| Recommended Application | General sheet-metal fabrication | Long profiles and large sheet processing | Heavy fabrication and structural components | Extra-long beams, rails, and industrial sections |
| Laser Source Power | 3–6 kW | 6–12 kW | 12–20 kW | 15–30 kW |
| Laser Type | Continuous-wave fiber laser | Continuous-wave fiber laser | Continuous-wave fiber laser | Continuous-wave fiber laser |
| Maximum Mild-Steel Cutting Thickness* | 20–25 mm | 25–35 mm | 35–50 mm | 40–60 mm |
| Maximum Stainless-Steel Cutting Thickness* | 10–16 mm | 16–25 mm | 25–40 mm | 30–45 mm |
| Maximum Aluminum Cutting Thickness* | 8–12 mm | 12–20 mm | 20–30 mm | 25–35 mm |
| Maximum Positioning Speed | 80–100 m/min | 80–120 m/min | 80–120 m/min | 80–100 m/min |
| Maximum Acceleration | 0.8–1.0 G | 0.8–1.2 G | 0.8–1.2 G | 0.6–1.0 G |
| Positioning Accuracy | ±0.05 mm/m | ±0.05 mm/m | ±0.05 mm/m | ±0.05 mm/m |
| Repeatability | ±0.03 mm | ±0.03 mm | ±0.03 mm | ±0.03 mm |
| Typical Table Load Capacity | 1,000–1,500 kg | 1,500–2,000 kg | 2,000–3,000 kg | 2,500–4,000 kg |
| Drive System | Dual-drive rack-and-pinion system | Dual-drive rack-and-pinion system | Dual-drive rack-and-pinion system | Dual-drive rack-and-pinion system |
| Machine Frame Requirement | Stress-relieved welded steel frame | Reinforced stress-relieved steel frame | Heavy-duty reinforced steel frame | Segmented heavy-duty steel frame |
| Automatic Height Control | Capacitive sensing, typically 0.5–1.0 kHz | Capacitive sensing, typically 0.5–1.0 kHz | Capacitive sensing with collision protection | Capacitive sensing with collision protection |
| Assist Gas Options | Oxygen, nitrogen, and compressed air | Oxygen, nitrogen, and compressed air | Oxygen, nitrogen, and compressed air | Oxygen, nitrogen, and compressed air |
| Recommended Nitrogen Pressure | 10–20 bar, depending on thickness | 12–25 bar, depending on thickness | 15–30 bar, depending on thickness | 15–30 bar, depending on thickness |
| Cooling System | Industrial water chiller with dual temperature control | Industrial water chiller with dual temperature control | High-capacity industrial water chiller | High-capacity industrial water chiller |
| Electrical Supply | Three-phase, commonly 380–415 V, 50/60 Hz | Three-phase, commonly 380–415 V, 50/60 Hz | Three-phase, commonly 380–415 V, 50/60 Hz | Three-phase, commonly 380–415 V, 50/60 Hz |
| Expected Cutting Priority | Balanced speed, precision, and operating cost | Long-part capability and production flexibility | High throughput and thick-material capacity | Maximum workpiece length and industrial productivity |
| Most Important Selection Factor | Power matched to material thickness | Bed length, frame rigidity, and automatic nesting | Thermal stability, gas delivery, and motion accuracy | Long-axis synchronization, loading method, and floor space |