| 01 | High-capacity power switching specialist | PC-class and CB-class automatic transfer switches; open and enclosed assemblies | 100–6,300 A | AC 400–690 V | Break-before-make transition; optional delayed transition; motor-driven switching mechanism | Utility/generator sensing, phase-loss detection, undervoltage and overvoltage protection, manual-auto selection | IEC 60947-6-1; IEC 60947-2; applicable CCC certification | Data centers, hospitals, airports, large commercial buildings, industrial plants |
| 02 | Industrial and generator integration specialist | Dual-power ATS panels, generator changeover systems, bypass-isolation configurations | 63–4,000 A | AC 380–690 V | Open transition; adjustable transfer and retransfer delay; generator start signal output | Three-phase voltage and frequency monitoring, emergency-stop input, remote test, RS-485 communication | IEC 60947-6-1; IEC 61439-1/-2 for assembled switchboards | Manufacturing facilities, telecom sites, emergency power rooms, logistics centers |
| 03 | Compact modular ATS manufacturer | Integrated PC-class ATS, modular panel units, DIN-rail control accessories | 16–630 A | AC 220–440 V | Fast open transition; electrically and mechanically interlocked switching | LED status indication, source availability display, phase-sequence monitoring, local manual override | IEC 60947-6-1; IEC 60529 enclosure protection options | Small commercial buildings, retail facilities, residential backup systems, small workshops |
| 04 | Critical-load power continuity specialist | High-speed ATS, bypass transfer equipment, maintenance-isolation systems | 100–3,200 A | AC 400–480 V | Open transition; optional in-phase transfer where compatible with the connected power sources | High/low voltage thresholds, frequency supervision, event logging, remote alarm contacts, communication gateway | IEC 60947-6-1; IEC 61439-1/-2; project-specific data-center requirements | Data centers, medical imaging centers, financial facilities, semiconductor production |
| 05 | Photovoltaic and microgrid transfer specialist | AC-coupled microgrid ATS, utility-generator ATS, energy-storage changeover panels | 40–1,600 A | AC 380–800 V | Open transition with configurable source priority; synchronization-ready control options | Grid-loss detection, frequency and phase monitoring, dry-contact control, Modbus communication | IEC 60947-6-1; IEC 61439-1/-2; local grid-connection requirements vary by project | Solar microgrids, energy-storage systems, remote facilities, low-carbon commercial buildings |
| 06 | Marine and transport power systems specialist | Compact enclosed ATS, vibration-resistant transfer panels, generator-to-load switching systems | 40–1,250 A | AC 220–690 V | Electrically operated open transition; manual emergency transfer facility | Source status indication, phase-failure protection, programmable delay timers, remote alarm output | IEC 60947-6-1; enclosure and installation requirements depend on marine or transport approval | Ports, vessels, rail facilities, tunnels, traffic control and transport infrastructure |
| 07 | Building-services and commercial distribution specialist | MCCB-based ATS, molded-case transfer assemblies, fire-pump and emergency-load panels | 100–1,600 A | AC 380–440 V | Break-before-make operation; adjustable transfer, retransfer and generator-start delays | Utility/emergency source indication, automatic/manual modes, fire-control interface, remote monitoring contacts | IEC 60947-6-1; IEC 61439-1/-2; local fire and building codes | Office buildings, shopping centers, hotels, schools, fire-pump and life-safety systems |
| 08 | Low-voltage distribution panel specialist | Fixed and withdrawable ATS panels, feeder transfer units, custom low-voltage switchboards | 250–5,000 A | AC 400–690 V | Mechanically interlocked circuit-breaker transfer; open transition with optional bypass arrangement | Digital metering, source health analysis, protection relay coordination, PLC or BMS interface | IEC 60947-6-1; IEC 61439-1/-2; IEC 60947-2 | Heavy industry, water treatment plants, mining, infrastructure and utility substations |
| 09 | OEM and customized enclosure specialist | Customer-specified ATS assemblies, stainless-steel enclosures, outdoor and harsh-environment configurations | 63–2,500 A | AC 220–690 V | Open transition; selectable transfer logic; customized source-priority sequences | Programmable controller, remote I/O, RS-485 or Ethernet options, customized alarm and metering functions | IEC 60947-6-1; IEC 61439-1/-2; enclosure rating selected according to installation conditions | Oil and gas support facilities, outdoor telecom, construction projects, process industries |
| 10 | Residential and light-commercial backup specialist | Miniature and molded-case ATS, single-phase and three-phase generator changeover units | 16–400 A | AC 220–400 V | Automatic open transition; utility-to-generator and generator-to-utility transfer | Basic source detection, adjustable delay, LED indicators, generator start/stop dry contacts | IEC 60947-6-1; IEC 61439-3 where applicable; national installation requirements | Homes, villas, small offices, convenience stores, rural backup and small generator systems |