| Continuous operating temperature | Approximately 900–1,100 °C for many industrial applications, depending on tube geometry, load, atmosphere, and installation. | Quartz retains useful high-temperature performance, but long exposure near the upper range can accelerate deformation, devitrification, or contamination. | Choose a tube with a continuous rating above the actual process temperature. Do not use the short-term maximum as the normal operating temperature. |
| Softening point | About 1,660–1,670 °C for fused silica. | This is a material property, not a recommended working temperature. A tube can lose dimensional stability well below its softening point when heated for long periods. | Use the manufacturer’s continuous-use rating for the specific diameter, wall thickness, and mounting arrangement. |
| Thermal shock resistance | Low coefficient of thermal expansion, typically about 0.5 × 10−6 K−1 near room temperature. | Quartz generally tolerates rapid temperature changes better than ordinary glass, but scratches, chips, uneven heating, and constrained mounting can still cause fracture. | Avoid point loads and rigid restraints. Heat and cool uniformly, especially when the tube contains liquid or has significant wall-temperature differences. |
| External pressure or vacuum | Quartz tubes are commonly used in vacuum systems, but there is no universal pressure rating based on material alone. | Collapse and fracture depend strongly on outside diameter, wall thickness, unsupported length, ovality, surface flaws, temperature, and end connections. | For vacuum service, verify the tube’s implosion rating and use appropriate shielding. Never infer a safe pressure from tensile strength alone. |
| Internal pressure | A thin-wall screening relationship is hoop stress σ ≈ P × D ÷ (2 × t), where P is pressure difference, D is tube diameter, and t is wall thickness. | This relationship is not a complete design rating because quartz is brittle and sensitive to surface defects, stress concentrations, thermal gradients, and end geometry. | Use a qualified pressure-vessel calculation, conservative safety factors, inspection, and a design-specific certificate before applying positive pressure. |
| Water and dilute mineral acids | Generally excellent resistance at moderate temperatures to water, hydrochloric acid, nitric acid, and sulfuric acid in many concentrations. | Actual performance depends on concentration, temperature, exposure time, impurities, and mechanical stress. | Confirm compatibility for concentrated or hot acids, particularly when the tube is under thermal or mechanical stress. |
| Hydrofluoric acid and fluoride compounds | Poor resistance. Hydrofluoric acid attacks silica and can etch or dissolve fused quartz. | Even relatively small exposure can damage the surface and reduce mechanical reliability or optical quality. | Do not select quartz for HF service unless a validated, application-specific compatibility assessment supports it. |
| Alkaline solutions and alkaline vapors | Resistance is limited, especially with hot or concentrated alkalis such as sodium hydroxide or potassium hydroxide. | Attack generally becomes more significant as temperature and alkalinity increase. | Use a compatibility chart and test the exact chemical concentration and temperature before final selection. |
| Hot phosphoric acid | Can attack fused quartz at elevated temperatures, with risk increasing as temperature and exposure time rise. | A tube that performs well with dilute or cool acid may not be suitable for hot concentrated service. | Obtain a temperature-specific compatibility assessment for heated phosphoric-acid processes. |
| Gas and atmosphere compatibility | Quartz is widely used in air, inert gases, and many laboratory or semiconductor process atmospheres, subject to contamination and temperature limits. | Reactive gases, moisture, deposits, and process by-products can change surface condition and service life. | Evaluate the complete gas chemistry, flow rate, pressure, moisture level, and expected deposits—not only the base gas. |
| Dimensional and installation factors | Larger diameter, thinner walls, longer unsupported spans, scratches, chips, and rigid fittings reduce mechanical margin. | Mechanical reliability can be governed by geometry and handling damage rather than bulk material properties. | Specify outside diameter, inside diameter, wall thickness, length, tolerances, finish, support spacing, and end-treatment requirements. |